BALANCE LOAD 1/3 PHASE TRMS KUSAM MECO 351
POWER CLAMP-ON METER WITH PC INTERFACE 17 FUNCTIONS 23 RANGES
Main features:
- Ultra-Slim jaw to access tight places.
- 600A AC Clamp-on + Multimeter ranges
- 600V AC/DC input protection on all functions
- AC True RMS Voltage and Current functions.
- Balanced-Load 1-phase / 3-phase Power W, VA & VAR measurements.
- Dual display Power Factor (PF) & A-Lags-V Phase-Shift indication
- Auto VM ™ AutoVA (Auto Selection on ACV, DCV or ACA functions)
- Power measurement of Selectable W, VAR & VA with dual-display Total Power Factor features.
- Display PEAK-rms HOLD & Data Hold function.
- Fast Peak-rms Hold (65ms to 90%) for In-rush ACA & ACV readings.
- Measure line-level ACV Frequency via test leads
- Measure non-invasive ACA frequency via clamp jaws.
- Battery Cover with probe holders.
- Fast Audible Continuity.
- PC-Comm computer interface capabilities (Optional).
GENERAL SPECIFICATIONS:
- Sensing : True RMS sensing
- Jaw opening & Conductor diameter : 26mm max
- Display : Voltage Function : 6000 counts LCD display
- Power, Ohm & Hz functions : 9999 counts LCD display
- ACA clamp-on function : 4000 counts LCD display
- Update Rate : Power function : 1 per second nominal Voltage, ACA clamp-on, Ohm, & Hz functions :4 per second nominal
- Polarity : Automatic
- Altitude : Operating below 2000m
- Low Battery : Below approx 2.4V
- APO Timing : Idle for 17 minutes
- APO Consumption : 10mA typical
- Operating Temperature : 0 C to 40 C
- Relative Humidity : Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% relative humidity at 40oC
- Storage Temperature : -20 C to 60 C, < 80% R.H. (With battery removed)
- Temperature Coefficient : nominal 0.15 x (specified accuracy) / 0C @ (0oC-18oC or 28oC-40oC), or otherwise specified.
- Power supply : Standard 1.5V AAA Battery x 2.
- Power Consumption : Voltage, ACA, Hz & Power functions : 10mA typical
- Ohm function : 4mA typical
- Dimension : 189(L) x 78(W) x 40(H) mm
- Weight : Approx. 192 gms
SAFETY:
- Meets IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., CAN/CSA C22.2 No. 61010.1-0.92, IEC61010-2-032, EN61010-2-032, UL61010B-2-032 & CAN/CSA C22.2 No. 61010-2-032-04: Measurement Category : III 600 Volts AC & DC.
- Pollution degree : 2
- E. M. C. : Meets EN61326-1: 2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m : Total Accuracy = Specified Accuracy + 45 digits Performance above 3V/m is not specified
- Overload Protections : ACA Clamp-on jaws : AC 600A rms continuous + & COM terminals(all functions) : 600VDC/VAC rms
- Rugged Fire-retarded casing
- LVD EN61010-1 & EN61010-2-032 CAT III 600V
ACCESSORIES:
- Test leads (pair), Battery installed, User's Manual, Carrying Case.
OPTIONAL ACCESSORIES:
- PC interface Kit, (including BUA-2303 USB-to-Serial adaptor, BA-1XX optical adapter black, BC-100R cable & Bs Software CD)