Main features:

  • Selectable Power parameters of W, VAR & VA with Total Power Factor in dual-display.
  • AutoVA (Auto Selection on ACV, DCV or ACA functions)
  • Backlight display
  • kWHr Recording
  • Display Hold & PEAK-rms HOLD
  • PC-Comm computer interface capabilities

GENERAL SPECIFICATIONS:

  • Sensing : True RMS sensing
  • Jaw opening & Conductor diameter : 26mm max
  • Display : Voltage Function : 6000 counts LCD display Power, Ohm & Hz functions : 9999 counts LCD display ACA clamp-on function : 4000 counts LCD display
  • Update Rate :Power function : 2 per second nominal Voltage, ACA clamp-on & Ohm functions : 2 per second nominal Hz function : 1 per second nominal
  • Operating Temperature : 0 C to 40 C
  • Relative Humidity : Maximum relative humidity 80% for temperature upto 31oC decreasing linearly to 50% relative humidity at 40oC
  • Polarity : Automatic
  • Low Battery : Below approx 2.4V
  • Altitude : Operating below 2000m
  • Storage Temperature : -20 C to 60 C, < 80% R.H. (With battery removed)
  • Temperature Coefficient : nominal 0.15 x (specified accuracy) / 0C @ (0oC-18oC or 28oC-40oC), or otherwise specified
  • Power supply : Standard 1.5V AAA Battery x 2.
  • Power Consumption : Voltage, ACA, Hz & Power functions : 11mA typical
  • Ohm function : 5.5mA typical
  • APO Timing : Idle for 30 minutes
  • APO Consumption : 4mA typical
  • Dimension : 189(L) x 78(W) x 40(H) mm
  • Weight : Approx. 192 gms

SAFETY:

  • Meets IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., IEC61010-2-032, EN61010-2-032, UL61010B-2-032.
  • E. M. C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-7, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m : Total Accuracy = Specified Accuracy + 50 digits Performance above 3V/m is not specified
  • Measurement Category : CAT III 600Volts AC & DC
  • Pollution degree : 2
  • Overload Protections : ACA Clamp-on jaws : AC 600A rms continuous + & COM terminals(all functions) : 600VDC/VAC rms
  • LVD EN61010-1 & EN61010-2-032 CAT III 600V

ACCESSORIES:

  • Test leads (pair), Battery installed, User's Manual, Carrying Case.

OPTIONAL ACCESSORIES:

  • PC interface Kit, (including BUA-2303 USB-to-Serial adaptor, BA-1XX optical adapter black, BC-100R cable & Bs Software CD)